91久久久国产精品视频-国产麻豆精品系列一区二区-日韩中文字幕丝袜一区-亚洲日韩精品毛片一区二区三区

PRODUCT
DC26 Series - Temperature and Humidity Controller
Basic Series
Intelligent Series
DC28 Series - Multifunction Electric Meter
DC2800
H-Series
Z-Series
E-Series
X-Series
K-Series
D-Series
S-Series
TRPC Series - Reactive Power Compensation Controller
TRPC Controller
DC29 Series - Electric Energy Transmitter
1-way Transmitter
2-way Transmitter
3-way Transmitter
Multifunction Transmitter
DC30 Series - Moter Protection Controller
 
CONTACT US

Changzhou Dacan Electronic Co., Ltd

Mob: +86(0)13915077376

Tel: +86-519-85606622

Fax: +86-519-85607968

E_mail: sales@czdacan.com

Web: www.oudz.cn

S-Series
Three-phase Digital Display Measuring and Controlling Current Meters DC284I-AS4

1. Summarize

Three-phase Programmableintelligent digital display measuring and controlling meters are applied inelectric power network and automatic control system, mainly measuring all theparameters in the power system, such as current, voltage, frequency, powerfactor, active power, reactive power and so on. In according to its additionalfunctions, the meters can be divided into X, K, D, S four series.

X series of intelligent digitaldisplay meters, mainly measure and display the electrical parameters in theelectric power network, such as current, voltage, power, frequency and powerfactor and so on, with the features of intuitive display, high precision, goodreliability, anti-vibration, etc. AC True effective value measurement can beused to a serious wave distortion place.

On the basis of X series ,Kseries intelligent digital display meters have added with the functions ofsetting ratio keyboard and one channel RS485 communication interfaceoutput(supports Modbus RTU protocol) in order to facilitate digital displaymeters in the group networking.

D series digital displaytransmission meters on the basis of X Series meters have added with thefunctions of analog transmitting output(4-20m A and so on) and one channel RS485communication interface which supports Modbus-RTU protocol, and can be directlythree lines digital display or single-line digital switch.

S series Digital alarm monitoringcontrol meters have increased the functions of relay output (to achieve “theexcess limit alarm or telecontrol function”) on the basis of X series meters: RS485digital interface which supports Modbus-RTU implement “remote” function, thevariable ratio and communication parameters can be easily and momentarily setthrough meter panel buttons.

The Products meet the standardof GB/T22264.1-2008, GB/T 13978-2008.

2.Typical Product Pictures

3. Models and Meaning of Products

4.Products Models

Model

Product function

DC284I-2S4

DC284I-9S4

DC284I-AS4

Real-timemeasurement

Three-phase voltage

-

-

-

Three-phase current

Active power

-

-

-

Reactive power

-

-

-

Power factor

-

-

-

Analog output

AO (DC4-20mA)

-

-

-

Relayoutput

DO (AC250V/5A ,

Remote/Alarm

On-off input

DI (Passive stem node)

-

-

-

Communicationinterface

RS485, Modbus-RTU

-

-

-

Display mode

Three-lineLED

Panel size (mm)

120x120

96x96

74x74

Hole size (mm)

111x111

91x91

67x67

Installation mode

PanelMounting

Remark:

1”means the model has the function.

2“ - “ means the model doesn’thave such function.

3The number means channel, forexample: 2 means the model has the function with 2 channels.

5.Technical Specifications

Description

Parameters

Precision grade

Electriccapacity metering: active electric energy: 0.5 class, reactive electricenergy grade:1.0, transmission output grade 0.5

Display mode

LEDdisplay

Input signal

Measurement network

Three-phasefour-wire V34/Three-phase three-wire V33

Voltage

Rated voltage

AC100V,AC400V

Excess load

Continuance:1.2 times; Instantaneous: 2 times (10s)

Power consumption

0.6VA(each phase)

Impedance

200kΩ

Current

Rated current

AC5A /AC1A

Excess load

Continuance: 1.2 times;Instantaneous: 10 times (5s)

Power consumption

0.4VA(each phase)

Impedance

20mΩ

Frequency

45-65Hz(?0.01Hz)

Electric energy

Bi-directionalActive/Reactive electric energy metering

Power supply

Working scope

AC/DC85-264V

Power consumption

5VA

Function modules

Electric energy pulse

Passiveoptical coupler collector output

Communication interface

1-wayRS485 communication interface, Modbus-RTU Protocol

Transmission output

0-20mA/4-20mA/0-5V/1-5Vtransmission output, programmable to setting transmission items and relativeoutput data.

Security

Insulation resistance

100MΩ

Resist pressure

Inputvoltage1kV,  Input and output2kV,Power supply and output2kV

Work environment

Temperature

-10℃~55

Relative humidity

93RH

Altitude

Non-corrosive gas forum,Altitude 2500m

storage environment

Temperature

-20℃~75

Relative humidity

93RH

6.Outline Dimension

DC284I-2S4

DC284I-9S4

DC284I-AS4

7.Typical Signal Input Wiring Diagram

 Note: the above diagram is only for reference, the actual parameters in the factory shall prevail.

Wiring Instruction:

  • Inputvoltage cannot exceed rated input voltage (100V or 400V), otherwise shouldconsider using PT, in order to make maintenance easily, advice to use connectorbar.

  • Standardrated input current is 5A or 1A, if in the situation of more than 5A, shoulduse exterior CT. If using CT with other meters, wiring method should be seriesconnection, before removing the wire of input current, make sure that cut offCT one circuit or Short sub-secondary circuit in advance, in order to makemaintenance easily, advice to use connector bar.

  • Makesure input voltage is correspond with input current, phase no. consistent,directions are consistent, otherwise the value and the symbol of power andelectric energy will be wrong.

  • Themeter can work in three-phase four-wire or three-phase three-wire mode, theusers should select the appropriate wiring way based on the site situation.Usually under the situation without center line, use three-phase three-wiremode, while three-phase four-wire mode under the situation of center line.Please pay attention that onsite wiring mode must be consistent with the wiringdefault setting of the meter, otherwise the data of measured by meters will beincorrect.

    8. OrderingExample

    When order please specify the required models, power supply,signal input, the transformation ratio, display requirements and relativecontent. Accuracy class, the default is Class 0.5. For example, if need Class0.2, please specify when ordering.

  • Model: DC284I-AS4

  • Power supply: AC 220V

  • Signal Input: AC380V

  • Signal Output: AC250V/5A

  • Other: otherfactory pre-sets (if no indication when ordering, ex-factory products will bedelivered in accordance with the default setting).


BACK